When every second matters, the Philips Heartstart MRX stands as a powerful, reliable, and intelligent solution for emergency response and cardiac care. Designed for hospitals, ambulances, and critical care units, this advanced defibrillator-monitor ensures rapid and accurate intervention during life-threatening situations.

Engineered with cutting-edge technology, the Heartstart MRX combines monitoring, defibrillation, and pacing capabilities into one compact unit. Healthcare professionals trust this device for its precision, speed, and ease of use, making it an essential addition to any medical facility. With UM Healthcare India Pvt Ltd, you receive not just a product—but a dependable partner in saving lives.

Philips MRx Specifications

MRx Dimensions (Without External Paddles)

 

  • Width: 12.4 in (31.3 cm)
  • Depth: 8.3 in (21 cm)
  • Height: 11.7 in (29.5 cm)

 

MRx Dimensions (With External Paddles)

 

  • Width: 13.4 in (34 cm)
  • Depth: 8.3 in (21 cm)
  • Height: 13.6 in (34.5 cm)

 

Weight

 

  • 13.2 lb (6kg): Base unit with 1 MRx battery, pads, and pads cable.
  • +4.1 lb (1.86 kg): With added MRx carrying case.
  • +2.5 lbs. (1.1 kg): With added MRx paddle tray and external standard paddles.

 

Environmental

 

  • Water Resistance: Meets IEC 60601-2-4
  • Solids Resistance: IP2X
  • Temperature
    • Operating: 32º – 113º F (0º – 45º C)
    • Storage: -4º – 158º F (-20º – 70º C)
  • Humidity: Operating: 0% to 95% relative
  • Safety: Meets EN 60601-1, UL 2601-1, CSA C22.2 No. 601-1-M90 CSA, EN 60601-2-4

 

MRx Display

 

  • Dimensions: 8.4 in diagonal (12.8 cm x 17.1 cm)
  • Type: TFT color LCD
  • Resolution: 640 x 480 pixels (VGA)
  • Wave Viewing Time: 5 seconds (ECG)

 

Strip Chart Printer

  • Printer
    • Standard: 50 mm (paper width) thermal array printer.
    • Optional: 75 mm (paper width) thermal array printer.
  • Continuous ECG Strip: Prints primary ECG lead with event annotations and measurements in real-time or with a 10-second delay.
  • Auto Printing: The printer can be configured to print significant events, charge, shock, and alarms.
  • Reports: Event Summary, 12-Lead, Vital Signs Trending, Operational Check, Configuration, Status Log, and Device Information.
  • Paper Size
    • 1.97 in (50 mm) W by 100 ft. (30 m) L.
    • 2.95 in (75 mm) W by 100 ft. (30 m) L.

Defibrillator

  • Model: MRx (M3535A)
  • Waveform: Biphasic Truncated Exponential. Waveform parameters adjusted as a function of patient impedance.
  • Output Energy: Manual (selected): 1-10, 15, 20, 30, 50, 70, 100, 120, 150, 170, 200 Joules maximum energy, limited to 50 Joules for internal defibrillation. AED Mode (single energy output): 150 Joules into a 50-ohm load.
  • Charge Time on the MRx: Less than 5 seconds to 200 Joules with a new, fully charged lithium-ion battery at 25º C.
  • Shock Delivery: Via multifunction defib electrode pads or paddles.
  • Quick Shock: Less than 10 seconds from the cessation of CPR to shock delivery.
  • Patient Impedance Range
    • Minimum: 15 ohm (internal defibrillation); 25 ohm (external defibrillation).
    • Maximum: 150 ohm.
  • AED Mode on the MRx: Shock advisory sensitivity and specificity meet AAMI DF-39 guidelines.

MRx Battery

  • Type: 6.0 Ah, 14.8 V, rechargeable lithium ion.
  • Dimensions
    • Height: 6.5 in (165 mm)
    • Width: 3.8 in (95 mm)
    • Depth: 1.6 in (42 mm)
    • Weight: 1.6 lbs. (0.73 kg)
  • Charge Time: Approximately 3 hours to 100%, 2 hours to 80%.
  • Capacity
    • At least 5 hours of monitoring with ECG, SpO2, CO2, temperature, and two invasive pressures monitored continuously, NBP measured every 15 minutes, and 20 200J discharges (with a new, fully charged battery, operating at room temperature, 25º C).
    • At least 3.5 hours of monitoring with ECG, SpO2, CO2, temperature, and two invasive pressures monitored continuously, NBP measured every 15 minutes, and pacing at 180ppm at 160mA.
  • Battery Indicators
    • Battery gauge on battery, the capacity indicator on display; flashing RFU indicator, chirp, and ‘Low Battery’ message appears on display for low battery condition when 10 minutes of monitoring time and 6 maximum energy discharges remain (with a new battery at room temperature, 25º C).

Data Storage

  • Internal: 12 hours of continuous ECG waveforms and events, maximum capacity of 55 event summaries.
  • Data Card: 60 event summary reports or 240 megabytes of patient data.

ECG and Arrhythmia Monitoring

  • Input
    • Up to 4 ECG waves displayed and up to 2 ECG waves print simultaneously.
    • Lead I, II, or III obtained through a 3-lead ECG cable and separate monitoring electrodes. With a 5-lead cable, obtain leads aVR, aVL, aVF, or V. Pads ECG obtained through 2 multifunction defibrillation electrode pads.
  • Lead Fault: ‘Lead Off’ message and dashed line displayed, if an electrode or lead wire becomes disconnected.
  • Pads Fault: Dashed line displayed if a pad becomes disconnected.
  • Heart Rate Display: Digital readout on display 15 to 300 bpm, accuracy ±10%.
  • Heart Rate Arrhythmia Alarms: HR, Asystole, VFIB/VTACH, VTACH, extreme tachycardia, extreme bradycardia, PVC rate, Pacer not capture, Pacer not pacing.
  • ECG Size: 2.5, 5, 10, 20, 40 mm/mV, autogain.

Available Options

  • Non-Invasive Pacing: SpO2 pulse oximetry.
  • Non-Invasive Blood pressure: CO2 monitoring.
  • Invasive Blood Pressure (2 lines): Continuous temperature monitoring.
  • 12-Lead Acquisition: 12-lead transmission.
  • Q-CPR Measurement and Feedback: Audio recording.
  • ACI-TIPI & TPI Predictive Instruments: Periodic clinical data transmission.
  • Batch/LAN Data Transfer