Advanced Critical Care Ventilation You Can Trust
At UM Healthcare PVT. LTD., we deliver proven critical care solutions designed to support clinicians and save lives. The Vyaire Care Fusion Viasys Vela Ventilator is a trusted ICU ventilator known for its precision, reliability, and adaptability across a wide range of patient needs. Engineered for intensive care environments, this ventilator supports both invasive and non-invasive ventilation with exceptional accuracy.
Hospitals and healthcare professionals rely on the Vyaire Care Fusion Viasys Vela Ventilator for its consistent performance, making it a dependable choice for adult and pediatric respiratory support.
Durable Design Built for ICU Demands
Designed for continuous operation, the Vyaire Care Fusion Viasys Vela Ventilator features a compact yet robust build suitable for busy hospital environments. Its mobility allows easy movement between departments without disrupting patient care. High-quality components ensure long service life and stable performance even under demanding conditions.
When you buy from UM Healthcare PVT. LTD., you receive genuine equipment backed by reliable support and industry expertise, giving healthcare facilities peace of mind.
Vyaire CareFusionViasys Vela Specifications
Dimensions
- Pneumatic Module
- Height: 10.5 in (26.7 cm)
- Width: 17 in (43.2 cm)
- Depth: 16 in (40.6 cm)
- User Interface Module
- Height: 13.75 in (35 cm)
- Wdth: 16.25 in 941.3 CM)
- Depth: 2.5 in (6.4cm)
- Viewable size: 12.1 in (diagonal
- Resolution: 800 x 600
- Weight:
- Ventilator (includes User Interface Module): 83 lb or 37,6 kg
- Ventilator and Compressor (internal): 90 lb or 40,8 kg
Environmental
- Storage Temperature: -20° to 60° C (-4° to 140° F)
- Operating Temperature: 5° to 40° C (41° to 104° F)
- Barometric pressure: 760 to 545 mmHg
Battery Power
- 1 Hour of Ventilator Use on Internal Battery (Standard) / 30 minutes Ventilator/Compressor
- 8 Hours of Ventilator Use on Internal (Standard) and External (Optional) Battery / 2 hours Ventilator and Compressor
Advanced Gas Blending system
- Air/Oxygen Blending: 21 to 100%
- Internal Heliox Blending System (option): All concentrations up to 80/20
Advanced Patient Monitoring
- Proximal Hot Wire Flow Sensor
- 24-hour trending of monitored respiratory parameters
Electrical / Pneumatic / Input / Output
- Gas Composition FiO2: 21 to 100%
- Pneumatic Input
- Air / Heliox: 20 to 80 psig (1.38 to 5.52 bar)
- Compressor (internal): 3 to 10 psig (0.21 to 0.69 bar)
- Oxygen: 20 to 80 psig (1.38 to 5.52 bar)
- Electrical
- A/C: 100, 120, 230, 240 VAC, 47 to 65 Hz
- D/C (Internal/External Battery); 20 to29 VDC
- Data I/O
- Analog Inputs (x2): 0 to 1, 5 VDC
- Video Output: SVGA
- Nurse Call : N.O. or N. C.
Setup
- Humidifier: Active and passive humidification
- Patient setu:p Alphanumeric patient ID
- Leak compensation: ON, OFF
Mode
- Mode type: A/C, SIMV, CPAP/PSV, NPPV (AC, SIMV, CPAP/PSV), PRVC
- Breath type: Volume, pressure, APRV/BiPhasic
- Apnea backup: Volume, pressure
Primary Settings
- Rate: 2 to 80 bpm
- Tidal volume: 50 mL to 2.0 L
- Inspiratory pressure: 1 to 100 cmH2O
- Peak flow: 10 to 140 L/min, (180 L/min spontaneous maximum)
- Inspiratory pause: OFF, 0.1 to 2.0 seconds
- Inspiratory time: 0.3 sec to 10.0 seconds
- Pressure support ventilation: (PSV) OFF, 1 to 60 cmH2O
- PEEP: 0 to 35 cmH2O
- Flow trigger: 1 to 20 L/min
- %O2: 21% to 100% FiO2
- Pressure: high /pressure low 0 to 60 cmH2O/ 0 to 40 cmH2O
- Time high / time: low 0.3 to 30 seconds / 0.3 to
- NPPV Pinsp: 1 to 40 cmH2O
- NPPV PSV: OFF, 1 to 40 cmH2O
Advanced Settings
- Bias flow: 10 to 20 L/min
- Volume limit: 50 mL to 2.5 L (available in PRVC/Vsync only)
- Assured volume: OFF, 50 mL to 2.0 L
- PC flow cycle: OFF to 70%
- PSV cycle: 5% to 70%
- PSV Tmax: 0.3 to 3.0 seconds
- Waveform: Decelerating, square
- T high sync: 0% to 50%
- T high PSV: ON, OFF
- T low sync: 0% to 50%
- Sigh: ON, OFF
- Vsync: ON, OFF
Manual Controls
- Manual breath One breath
- Expiratory hold Maximum 6 seconds
- Inspiratory hold Maximum 6 seconds
- Increase O2 100% O2 for 3 minutes
- MIP/NIF Maximum 30 seconds
- Nebulizer 1 to 60 minutes, synchronized
Alarms
- High pressure 5 to 120 cmH2O
- Low pressure OFF, 2 to 60 cmH2O
- Low minute volume OFF, 0.1 to 99.9 L
- High breath rate OFF, 3 to 150 bpm
- Apnea interval 10 to 60 seconds
- Alarm volume 65 to 85 db at one meter
- Low EtCO2 OFF, 1 to 150 mmHg (0.1 to 20 kPa)
- High EtCO2 OFF, 5 to 150 mmHg (0.7 to 20 kPa)